What size heater for an 8x8 sauna?
A 10.5 kW heater. An 8 by 8 foot room with a 7 foot ceiling holds 448 cubic feet, and with a small window in the door it needs 9.3 kW.
| 8 × 8 ft room | Volume to heat | Power needed | Heater |
|---|---|---|---|
| Solid wood door | 448 cu ft | 9.0 kW | 9 kW |
| Wood door with a window | 464 cu ft | 9.3 kW | 10.5 kW |
| All-glass door | 503 cu ft | 10.1 kW | 10.5 kW |
| 8 ft ceiling, door with a window | 528 cu ft | 10.6 kW | 12 kW |
Rule: 1 kW for every 50 cubic feet, plus 3.94 cubic feet for each square foot of glass. What a 10.5 kW heater needs from your panel.
Adjust it for your room
Your sauna needs a
10.5 kW heater
It has 464 cu ft to heat, counting glass and bare surfaces, which takes 9.3 kW.
- 3
- 4.5
- 6
- 8
- 9
- 10.5
- 12
A 9 kW heater is rated to about 450 cu ft, so it would run at its limit here. The 10.5 kW heats faster and cycles less.
Electrical
| Draw at 240 Vsingle phase, hardwired, on its own circuit | 43.8 A |
|---|---|
| 125% for a continuous loadthe figure electricians size the circuit from | 54.7 A |
| Breakerwhat heater makers publish for this size | 50 A to 60 A, double-pole |
| Copper wireheavier for runs over about 50 ft | 6 AWG |
Heater makers publish their own breaker and wire sizes and they differ between models. The installation manual for your heater, and your electrician, decide. What the wiring involves.
What it costs to run
| Electricity per session40 min heat-up, then 30 min in use | 9.6 kWh |
|---|---|
| Cost per sessionlikely range $1.64 to $1.87 | $1.73 |
| Cost per month3 sessions a week at $0.18 per kWh | $22.52 |
| Cost per year | $270 |
How the size was worked out
| Room volume8 × 8 × 7 ft, or 12.7 m³ | 448 cu ft |
|---|---|
| Allowance for glass and bare surfaces4 sq ft × 3.94 cu ft | + 16 cu ft |
| Volume the heater must cover13.1 m³ | 464 cu ft |
| Heater power needed1 kW for every 50 cu ft | 9.3 kW |
10.5 kW heater. About $1.73 a session.See the working
Common questions
How many kW does an 8 x 8 sauna need?
An 8 by 8 foot sauna with a 7 foot ceiling holds 448 cubic feet and needs 9.0 kW with a solid door, so a 9 kW heater. With an all-glass door it needs 10.1 kW, a 10.5 kW heater.
What breaker does an 8 x 8 sauna need?
The 10.5 kW heater this room takes draws 43.8 amps at 240 volts. Makers publish a 50 to 60 A double-pole breaker and 6 AWG copper wire for that size.
How much does an 8 x 8 sauna cost to run?
About $1.73 a session at $0.18 per kWh: 9.6 kWh for a 40 minute heat-up and 30 minutes of use. Three sessions a week comes to about $22.52 a month.