12 kW sauna heater
A 12 kW electric heater covers a sauna of up to about 600 cubic feet and draws 50.0 amps at 240 volts.
Room size
| Largest room1 kW for every 50 cu ft | 600 cu ft |
|---|---|
| Comfortable up toheats faster, better outdoors in the cold | 540 cu ft |
| In metric | 17.0 m³ |
Common rooms that take this size, with a 7 foot ceiling and a small window in the door: 8 × 10 ft.
Breaker and wire
| Draw at 240 V, single phase | 50.0 A |
|---|---|
| With 125% for a continuous load | 62.5 A |
| Breaker, double-poleworked out from the 125% rule | 70 A |
| Copper wireheavier for runs over about 50 ft | 4 AWG |
| Output on a 208 V supply | 9.0 kW |
The heater is hardwired on its own circuit. Published breaker sizes differ between models of the same power, so the installation manual decides. On a 208 volt supply, found in some condos and commercial buildings, the same heater gives about three quarters of its rated heat. More on the wiring.
Running cost
A 40 minute heat-up at full power, then 30 minutes of use with the heater cycling about half the time, uses 11.0 kWh.
| Electricity price | Per session | Per month, 3 a week |
|---|---|---|
| $0.12 per kWh | $1.32 | $17.16 |
| $0.18 per kWh | $1.98 | $25.74 |
| $0.30 per kWh | $3.30 | $42.90 |
Common questions
What size room does a 12 kW sauna heater cover?
Up to about 600 cubic feet, at 1 kW for every 50 cubic feet. It is most comfortable below 540 cubic feet. Glass and bare masonry count as extra volume.
What size breaker does a 12 kW sauna heater need?
It draws 50.0 amps at 240 volts, and 62.5 amps once the 125% allowance for a continuous load is added. That points to a 70 A double-pole breaker and 4 AWG copper wire; confirm against the manual.
How much does a 12 kW sauna heater cost to run?
About 11.0 kWh for a 40 minute heat-up and a 30 minute session. That is $1.98 at $0.18 per kWh.
Check the size against your own room, glass and ceiling height.